MTC

 

 

 

4 way diverter valves

Installation information

‘P’ port is connected with inlet flow and ‘T’ port with tank line. ’A’ and ‘B’ valve ports are connected with actuator ports.

4 way diverter valves

Features

  • Cast iron body
  • Hardened spool

Operation

When the hand lever is in position 1 it allows flow
from ‘P’ to ‘B’ and ‘A’ to ‘T’. When the hand lever is in position 2 ‘P’ connects with ‘A’ and ‘T’ with ‘B’. When the hand lever is in the middle position ‘P’ port connects ‘T’ port.

Part Number
Port Size (BSP)
Max Flow (Litres/Min)
Maximum Pressure (BAR)
IDF4V02A
3/8"
35
250
IDF4V03A
1/2"
50
250
IDF4V04A
3/4"
90
250

 

 

 

4 way diverter valves

Specifications for Line Mounted Hydraulic Valves ...

 
 