4 way diverter valves
Installation information
‘P’ port is connected with inlet flow and ‘T’
port with tank line. ’A’ and ‘B’ valve
ports are connected with actuator ports.

Features
- Cast iron body
- Hardened spool
Operation
When the hand lever is in position 1 it allows flow
from ‘P’ to ‘B’ and ‘A’
to ‘T’. When the hand lever is in position 2 ‘P’
connects with ‘A’ and ‘T’ with ‘B’.
When the hand lever is in the middle position ‘P’
port connects ‘T’ port.
Part Number |
Port Size (BSP) |
Max Flow (Litres/Min) |
Maximum Pressure (BAR) |
IDF4V02A |
3/8" |
35 |
250 |
IDF4V03A |
1/2" |
50 |
250 |
IDF4V04A |
3/4" |
90 |
250 |
|