Product Features
  • Max working pressure: 200 bars
  • Proof pressure: 300 bars
  • Maximum speed: 0.5m/s
  • Temperature: – 30°C to + 90°C
  • Hydraulic mineral oil
Materials
  • Rod: CK45 chrome plated f7 Ra<0.2
  • Chrome thickness 20µ mini
  • Corrosion test: 120 hours NSS ISO9227 class9 (ISO4540) Hardness 900 HV
  • Tube: St 52.3 BK DIN 2393 /C tolerance H9/10. Ra<0.8µ
  • Gland: nitride hardening steel (38MF5)
  • Piston: Steel C35R
Seals
  • Rod: compact polyurethane lip seal + 1 wiper seal
  • Piston: compact polyurethane seal + nitrile
Protection
  • Priming paint black RAL9005 except on type 707.5 and 707.10 and wood splitter cylinder
  • Zinc plating on micro cylinders

Product Specification

Cylinder measurements relate to drawing shown in mm

Cylinder Ref ØA ØB Z (Stroke) C D E F G H  I J K L M N P  Volume  Unit Weight
74590/700T 45 90 700 135  20.5 185  37  100 35 25 45 64 837 3/8 45 45 4.6 Ltr 28 Kg
74590/1000T 45 90 1000 135  20.5 185  37 100 35 25 45 64 1137 3/8 45 45 6.5 Ltr 35 Kg
706/1000T 50 100 1000 151  25.5 280  42 115 44 30 48 60 1145 1/2 50 50 8.0 Ltr 50 Kg
706/1100T 50 100 1100 151  25.5 280  42 115 44 30 48 60 1245 1/2 50 50 8.6 Ltr 56 Kg
760100/1000T 60 100 1000 151  25.5 280 42 115 44 30 58 60 1145 1/2 50 50 8.0 Ltr 57 Kg
760110/1100T 60 110 1100 170  25.5 280  42 125 44 30 48 70 1255 1/2 50 50 10.5 Ltr 67 Kg
770100/1000T 70 100 1000 151  25.5 280  42 115 44 30 68 60 1145 1/2 50 50 8.0 Ltr 66 Kg
707/1000T 70 120 1000 151 280 50 140 55 82 1200 1/2 50 50 11.5 Ltr 92 Kg

Product Recommendations

– Protection of the circuit by a relief valve and a filter
– Check the oil cleanness (pollution)
– Bleed the air from the cylinder and the hydraulic circuit

The cylinder should not, under any circumstances, be used as a mechanical limit stop for moving loads.
Single-acting cylinders must be fitted with a tank return for unused power.

• Welding: do not weld on the tube. Dismount the cylinder to weld on the rod or on the base

• Storing: storage of extended cylinder, the rod must be greased. For high pressure cleaning, protect the rod.
The cylinder cannot be used to hold any loads. Mechanical locks must be used.
For double acting cylinders working as single acting, it is essential to connect the unused port to the tank

• Striping down: Warning : the piston is locked with glue (glue it again when re-assembling)