Denison PV – Piston Pump for Open Circuits

~ scroll down to find the part you need ~

General

The PV series pumps are variable displacement open circuit piston pumps with a design emphasis on operation economy. These axial piston pumps for open loop operation are suitable for rear drive in the PVT series configuration.
The PV pumps have a displacement of 0.88 to 7.93 cu. in/rev. (14,4 to 130,0 cc/rev.) with a continuous working pressure up to 4000 psi (280 bar): The pumps can be equipped with a pressure compensator, ventable compensator, load sensing or power limit control.

Mounting

The PV pumps have been designed to operate in a wide range of applications in industries where high pressure and variable flow are required at competitive cost.
These pumps are designed to operate in any position. The mounting hub and two bolt mounting flange are in conformance with SAE standards. The pump shaft must be in alignment with the shaft of the source driver and should be checked with a dial indicator. The mating pilot bore and coupling must be concentric. This concentricity is particularly important if the shaft is rigidly connected to the driven load without a flexible coupling.

Input Shaft Information
Splined:

The shafts will accept a maximum misalignment of 0.002 in. (0,06mm) total indicator reading when the pump is foot mounted and 0.001 in. (0,03 mm) when flange mounted. Angular misalignment at the male and female spline axis must be less than ±0,002 inch per inch radius (± 0,002 mm/mm). The coupling interface must be lubricated.

DENISON recommends lithium molydisulfide or similar grease. The female coupling should be hardened to 27/34 Rc and must conform to SAE-J498c, class 5 flat root side fit.

Keyed:

High strength heat treated keys must be used. Replacement keys must be hardened to 27-34 Rc. The key corners must be chamfered 0.03 – 0.04 in. (0,75-1,0 mm) at 45° to clear radii that exist in the keyway.

Side Load Capability

The PV series is designed for inline-drive and side loading on the shaft is not
recommended. If this is unavoidable consult your nearest DENISON HYDRAULICS representative.

Direct Equivalent

Replace your old Denison PV with the Continental HPV range of piston pumps. Output flow sizes are equal to the Denison pumps including the 6, 10, 15, 20 and 29 gallons per minute @ 1750 RPM units.  Contact us with your Denison PV part number for a direct Continental hydraulics HPV replacement pump.

Product Specification

Description PV6 PV10 PV15 PV20 PV29
 Displacement 0.88 in³/rev
{14.4 cm³/rev}
1.26 in³/rev
{20.6 cm³/rev}
2.09 in³/rev
{34.2 cm³/rev}
2.62 in³/rev
{42.9 cm³/rev}
 3.78 in³/rev
{61.9 cm³/rev}
 Continuous Pressure 3500 psi
{240 bar}
3500 psi
{240 bar}
3500 psi
{240 bar}
3500 psi
{240 bar}
3000 psi
{207 bar}
 Intermittent Pressure 4500 psi
{310 bar}
4500 psi
{310 bar}
4500 psi
{310 bar}
4500 psi
{310 bar}
4000 psi
{280 bar}
 Max Speed 3000 rpm 3000 rpm 2500 rpm 2400 rpm 2400 rpm
Rotating Inertia 2.00 lb in²
{.0006 kg m²}
3.3 lb in²
{.00099 kg m²}
7.87 lb in²
{.00233 kg m²}
11.97 lb in²
{.00355 kg m²}
21.84 lb in²
{.00647 kg m²}
Off-Stroke Compensator Response 50 ms 50 ms 50 ms 50 ms 50 ms
On-Stroke Compensator Response 120 ms 120 ms 120 ms 120 ms 120 ms
Max Compensator Setting 4000 psi
{276 bar}
4000 psi
{276 bar}
4000 psi
{276 bar}
4000 psi
{276 bar}
4000 psi
{276 bar}
Compensator Adjustment 650 psi/turn
{44.8 bar/turn}
650 psi/turn
{44.8 bar/turn}
650 psi/turn
{44.8 bar/turn}
650 psi/turn
{44.8 bar/turn}
650 psi/turn
{44.8 bar/turn}
Minimum Inlet at 1800 rpm -6.1 in-Hg
{-155 mm-Hg}
-6.1 in-Hg
{-155 mm-Hg}
-6.1 in-Hg
{-155 mm-Hg}
-6.1 in-Hg
{-155 mm-Hg}
-6.1 in-Hg
{-155 mm-Hg}
Maximum Inlet Pressure 50 psi
{3.4 bar}
50 psi
{3.4 bar}
50 psi
{3.4 bar}
50 psi
{3.4 bar}
50 psi
{3.4 bar}
Maximum Case Pressure 10 psi
{0.7 bar}
10 psi
{0.7 bar}
10 psi
{0.7 bar}
10 psi
{0.7 bar}
10 psi
{0.7 bar}
Input Mounting 82-2
(A)
101-2
(B)
101-2
(B)
127-2
(C)
127-2
(C)
Weight 24 lb
{11 kg}
36 lb
{16 kg}
43 lb
{20 kg}
57 lb
{26 kg}
73 lb
{33 kg}

Dension – PV – Piston Pump for Open Circuits – Datasheet

Denison – HPV Cross over Guide

Additional Information

Hydraulic Pump Units

Piston Pump

Manufacturer

Denison

Direct Alternatives

The Denison PV Piston Pump is no longer manufactured, fortunately the Continental Hydraulics HPV PowerFlow series of piston pumps is a direct replacement. Output flow sizes are equal to the Denison PV units and include the 6, 10, 15, 20 and 29 US gallons per minute sizes @ 170 RPM.
Four standard HPV series control options provide the customer with the flexibility to match the Denison PV pump series, including the standard Pressure compensated unit, the Load Sensing Compensator, Remote Compensator and the Horsepower limiting Compensator.

Please refer to our cross over guide in the downloads section for details or simply contact our sales department with your Denison code and we will confirm the correct Continental replacement.