Hydraulic Sequence Valve
Installation information
The ‘P’ port connects to the outlet port of the
first actuator and the ‘T’ port connects to the
inlet port of the second actuator.
Features
- Aluminium Body
- Cartridge Relief range 40 to 210 Bar
- No Leakage
Operation
When the first actuator exceeds the pre-set pressure, the
valve opens and allows flow to second actuator. To adjust
the setting of the spring, remove the cap from the end of
the cartridge and adjust clockwise to increase the setting
and anti-clockwise to reduce the setting. A free flow check
allows reverse flow from port ‘T’ to port ‘P’.
Setting range 40 to 210 BAR.
Part Number |
Port Size (BSP) |
Max Flow (Litres/Min) |
Maximum Pressure (BAR) |
VS3502B1 |
3/8" |
35 |
210 |
VS3503B1 |
1/2" |
35 |
210 |
Specifications
|